INSPECTION
1. INSPECT SHIFT SOLENOID VALVE SR
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Solenoid Connector (SR) - Solenoid Body (SR)
|
20°C (68°F)
|
11 to 15 Ω
|
(b) Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body. Then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes operating noise.
If the result is not as specified, replace the solenoid valve.
2. INSPECT SHIFT SOLENOID VALVE SLU
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Terminal 1 of shift solenoid valve SLU - terminal 2
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
(b) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, and then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes operating noise.
If the result is not as specified, replace the solenoid valve.
3. INSPECT SHIFT SOLENOID VALVE SL2
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Terminal 1 of shift solenoid valve SL2 - terminal 2
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
(b) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, and then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes operating noise.
If the result is not as specified, replace the solenoid valve.
4. INSPECT SHIFT SOLENOID VALVE SLT
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Terminal 1 of shift solenoid valve SLT - terminal 2
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
(b) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, and then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes operating noise.
If the result is not as specified, replace the solenoid valve.
5. INSPECT SHIFT SOLENOID VALVE SL1
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Terminal 1 of shift solenoid valve SL1 - terminal 2
|
20°C (68°F)
|
5.0 to 5.6 Ω
|
(b) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, and then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes operating noise.
If the result is not as specified, replace the solenoid valve.
6. INSPECT SHIFT SOLENOID VALVE S1
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Solenoid Connector (S1) - Solenoid Body (S1)
|
20°C (68°F)
|
11 to 15 Ω
|
(b) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, and then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes operating noise.
If the result is not as specified, replace the solenoid valve.
7. INSPECT SHIFT SOLENOID VALVE S2
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
|
Tester Connection
|
Condition
|
Specified Condition
|
|
Solenoid Connector (S1) - Solenoid Body (S1)
|
20°C (68°F)
|
11 to 15 Ω
|
(b) Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, and then check that the valve moves and makes an operating noise.
OK:
Valve moves and makes operating noise.
If the result is not as specified, replace the solenoid valve.
|